Authorized Toshiba Toshiba Microwave Service

Toshiba Microwave Repair — Unified Toshiba Microwave Service Number 16062 for All Models

Toshiba microwave repair by specialists in Japanese electronics — fix every Toshiba microwave fault (running but not heating, internal sparking, stuck door, loud noise, dim display) and every error code (H95, H96, H97, H98, H99). Toshiba microwave service hotline 16062 open now 24/7 — technician arrival within 1 hour in Greater Cairo with magnetron and high-voltage capacitor testing tools.

  • Original certified parts
  • 6-month written warranty
  • 1-hour arrival in Cairo
  • Toshiba-trained specialists
Toshiba Microwave
Toshiba
+15 years
24/7 available
6m warranty

Unified Toshiba Microwave Service Number & Authorized Service Center for All Toshiba Models

Toshiba Microwave

Toshiba microwaves are among the most widespread in Egyptian homes, thanks to Japanese quality in magnetron manufacturing — the core component responsible for generating microwave waves. Toshiba invented Inverter Microwave technology that modulates wave power instead of cycling on/off (like conventional microwaves), giving gentler cooking and more uniform heat distribution. When a Toshiba microwave fails, the first thing every customer searches for is the unified Toshiba microwave service number and a technician who understands the unit's high-voltage (4,000V) circuit specifics.

At Agent Site we provide authorized Toshiba microwave repair for every tier: Solo Microwave (heating only), Grill Microwave (with grill function), Inverter Microwave (modulated wave tech), and 3-in-1 Microwave (grill + convection + microwave). Technicians trained on Japanese electronics, specialized testing tools for magnetron, high-voltage capacitor, and diode, original Toshiba parts with invoices, and 6-month documented warranty. Technical inspection a price set after inspection, deducted from final repair invoice.

Important warning: Toshiba microwaves contain a high-voltage capacitor that stores 4,000V charge even after unplugging. Any attempt to open the unit yourself can cause a fatal electric shock. The Toshiba microwave hotline & unified service number 16062 is open now — phone diagnosis, find the nearest Toshiba microwave technician trained in capacitor discharge, estimated price before arrival, and a home visit within 1 hour in Cairo.
Fault Diagnosis

Common Toshiba Microwave Faults & Their Solutions

Before calling Toshiba customer service, check the symptom you see in your microwave. Every symptom has a physical cause and specific solution. Agent Site offers initial phone diagnosis on 16062 — describe the symptom and we'll give you the approximate cause and price.

01 Toshiba microwave runs but doesn't heat set after inspection Specialist

Microwave runs, light comes on, plate spins, timer counts down — but food comes out cold. The most common complaint to Toshiba microwave service number.

Most likely causes

  • 1 Burnt magnetron (most common — 70% of cases after 8 years use)
  • 2 Bulged or blown HV capacitor
  • 3 Burnt HV diode
  • 4 Faulty HV transformer
  • 5 Blown HV fuse

What to do

Original Toshiba magnetron replacement set after inspection. Capacitor replacement a price set after inspection. Diode replacement a price set after inspection. Transformer replacement set after inspection. Inspection determines the exact cause safely.

Estimated cost set after inspection
02 Sparks inside Toshiba microwave during operation Starting from a price set after inspection Easy DIY

You see blue, yellow, or orange sparks inside during cooking, sometimes loud crackling. Stop the unit immediately — critical sign.

Most likely causes

  • 1 Burnt waveguide cover/mica (most common)
  • 2 Grease buildup on upper interior wall
  • 3 Metal tray or aluminum foil mistakenly inside
  • 4 Damage inside cooking cavity (more serious)

What to do

Mica cover replacement a price set after inspection (cheapest microwave repair). Deep interior cleaning a price set after inspection. If cooking cavity is burnt, repair is difficult and not economically worth it.

Estimated cost Starting from a price set after inspection
03 Toshiba microwave completely dead (black screen) set after inspection Tech needed

You press the start button, no response. Screen is black, internal light off, no sound.

Most likely causes

  • 1 Blown main fuse (most common — 60% of cases)
  • 2 Power cord or wall outlet issue
  • 3 Burnt main control board
  • 4 Faulty low-voltage transformer for electronics
  • 5 Broken door safety switch (Monitor)

What to do

Fuse replacement a price set after inspection. Door safety switch replacement a price set after inspection. Main control board replacement set after inspection (major repair).

Estimated cost set after inspection
04 Toshiba microwave door stuck or doesn't close properly Starting from a price set after inspection Easy DIY

Door is hard to open, doesn't close tightly, or unit gives "door open" warning despite being closed. Common after years of use.

Most likely causes

  • 1 Broken or worn door handle
  • 2 Worn door hinges
  • 3 Damaged rubber gasket on door frame
  • 4 One of the three door safety switches faulty

What to do

Door handle replacement a price set after inspection. Hinge replacement a price set after inspection. Door gasket replacement a price set after inspection. Safety switch replacement a price set after inspection.

Estimated cost Starting from a price set after inspection
05 Toshiba turntable not rotating or rotating unevenly Starting from a price set after inspection Easy DIY

Glass turntable not moving despite the unit running, or rotates briefly then stops. Result: uneven cooking.

Most likely causes

  • 1 Burnt turntable motor
  • 2 Broken or misplaced roller ring
  • 3 Worn plastic turntable coupler
  • 4 Motor noise without actual rotation

What to do

Turntable motor replacement a price set after inspection. Roller ring replacement a price set after inspection. Turntable coupler replacement a price set after inspection. Quick job (30 min).

Estimated cost Starting from a price set after inspection
06 Loud abnormal noise from Toshiba microwave set after inspection Tech needed

Loud humming, grinding, or whistling during operation. Each sound indicates a different component.

Most likely causes

  • 1 Loud humming = magnetron near failure or stressed HV transformer
  • 2 Grinding = turntable motor or cooling fan
  • 3 Whistling = damaged or dust-clogged cooling fan
  • 4 Clicking = electrical contacts arcing

What to do

Cooling fan cleaning a price set after inspection. Cooling fan replacement a price set after inspection. Turntable motor replacement a price set after inspection. Magnetron noise = major repair set after inspection.

Estimated cost set after inspection
07 Toshiba microwave display dead or touchpad unresponsive set after inspection Tech needed

Unit is on (fan running, light on), but display is off or touch buttons unresponsive. Code H97 or H98.

Most likely causes

  • 1 Faulty touchpad membrane (code H97)
  • 2 Burnt main control board (code H98)
  • 3 Disconnected ribbon cable between display and main board
  • 4 Voltage spike burnt electronics

What to do

Touchpad replacement set after inspection. Main control board replacement set after inspection. Cable reconnection (included with inspection).

Estimated cost set after inspection
Capacities

We Repair All Toshiba Microwave Capacities & Types — Solo, Grill, Inverter, 3-in-1

Whatever your Toshiba microwave capacity (20, 24, 28, 32, 34, or 42 L) or type (Solo for heating, Grill for grilling, Inverter, or 3-in-1 convection), our technicians can service and fix every fault. Each tier has different electronic components and most-common faults — and we have specialized expertise in every one.

20 - 24 L

Toshiba Solo Microwave (Economic)

Singles, couples, quick heating and defrosting
  • 700-900W magnetron
  • simple LED display
  • 5-6 heating programs
Price range set after inspection
30 - 34 L

Toshiba Inverter Microwave

Mid-large families, precision cooking, Japanese cuisine fans
  • Inverter Magnetron
  • Auto Cook with humidity sensor
  • Sensor Reheat
  • LCD display
Price range set after inspection (typical service)
34 - 42 L

Toshiba 3-in-1 (Convection)

Large families, baking enthusiasts, oven alternative
  • Convection + Grill + Microwave
  • hot air fan
  • Auto Bake
  • 12-15 programs
Price range set after inspection (typical service)

Spare parts and labor prices are in the Pricing section below. Inspection fee — included with completed repair.

Models

Toshiba Microwave Models We Service — All Popular Egyptian Models

We provide Toshiba microwave repair for every model on the Egyptian market. If your model isn't listed below, call Toshiba customer service 16062 — we surely have experience servicing it.

ER-SS23(W)EE Solo
23 L
800W magnetronLED display5 power levels35-min timer
set after inspection (market price)
Best Seller
MW2-AG24P(BK) Grill
24 L
900W magnetron1000W quartz grillDigital display8 Auto programs
set after inspection
Best Seller
MM-EM34P(BS) Grill
34 L
1000W magnetronQuartz grillSensor Reheat10 programs
set after inspection
ML2-EM31P(BS) Inverter
31 L
1100W Inverter MagnetronAuto Cook with humidity sensorSensor Reheat12 programs
set after inspection
ML-EM45P(BS) 3-in-1 (Convection)
42 L
1100W magnetronHot air convection fanGrill elementAuto Bake, 15 programs
set after inspection
MW3-SAC24CF(BK) Grill
24 L
900W magnetronQuick DefrostChild LockBlack touch
set after inspection
Technologies

Toshiba Microwave Japanese Technologies & Their Common Faults

Toshiba microwaves feature unique Japanese engineering in magnetrons and high-voltage electronics. Each technology has its own faults, and our technicians are specialized in servicing every one with precise diagnostic tools and full safety.

01

Inverter Microwave Technology

Innovative Japanese technology from Toshiba replacing conventional on/off cycling with continuous wave modulation. Result: gentler cooking, evenly distributed heat, 30% better nutrient retention, lower power consumption. Core feature in ML-EM45P and ML2-EM31P models.

Benefits
  • Gentler, more uniform cooking
  • 30% better nutrient retention
  • Lower power consumption
  • Defrosting without cooking edges
Drawbacks
  • Inverter board sensitive to voltage fluctuation
  • Expensive board replacement
  • Requires specialist technician
Common faults

Code H96 (Inverter board failure), heating efficiency loss despite working magnetron, strange board noises, Inverter board burnout from voltage fluctuation

02

Magnetron Vacuum Tube (Microwave's Heart)

The magnetron is the most important part of a Toshiba microwave — a Japanese-made vacuum tube converting electricity to microwave waves at 2,450 MHz. Service life ~8-10 years; failure is the #1 cause of "Toshiba microwave runs but doesn't heat." Cannot be repaired — only replaced with original Toshiba unit.

Common faults

Unit runs but no heating (most common), internal sparking from magnetron corner, loud humming noise, high-voltage fuse keeps blowing

03

High Voltage Capacitor (Critical Component!)

High-voltage capacitor stores 4,000V charge and powers the magnetron. Maximum danger: retains charge for days after unplugging. Any attempt to open the microwave without specialized discharge tools can cause fatal shock. Our technicians are officially trained on Japanese safety protocols.

Common faults

Bulged or blown capacitor, unit completely dead, main fuse keeps blowing, sparks in upper area, electronic burning smell

04

Door Interlock Switches (3 Door Safety Switches)

Toshiba microwaves have 3 sequential door safety switches: the first and second confirm full door closure, the third (Monitor Switch) immediately cuts power if the door opens during operation. Failure of any switch prevents the unit from starting at all (radiation leak protection). 2nd most common cause of "microwave won't turn on."

Common faults

Unit won't start despite pressing Start, door is closed but unit thinks it's open, fuse blows immediately on door closure (broken Monitor Switch)

05

Waveguide Cover (Mica Sheet)

Mica sheet on the right interior wall covering the magnetron wave entry to the cooking cavity. Protects magnetron from food steam and grease. When it burns or accumulates dirt, continuous internal sparking appears and sometimes small flames. Replacement is very cheap (only a price set after inspection).

Common faults

Internal sparking at right wall, mica burning smell, blue or yellow sparks inside, blackened burnt sheet visible on inspection

06

Auto Cook + Humidity Sensor

Smart Toshiba microwaves have a humidity sensor that measures steam from food during cooking and automatically determines the end time without user input. Available in Auto Cook models. Sensor failure shows code H99.

Common faults

Code H99 (humidity sensor failure), Auto Cook not working, food comes out under/overcooked, unit stops before set time

07

Cooling Fan System (Magnetron Cooling)

Internal fan blowing cool air on the magnetron during operation to prevent overheating. If the fan fails, the magnetron overheats and trips thermal protection, or burns out completely. Code H95 indicates fan failure.

Common faults

Code H95 (cooling fan failure), unit shuts off after 2-3 minutes, loud or strange fan noise, hot smell from vents

Error Codes

Toshiba Microwave Error Codes — Complete Guide & Solutions

Smart Toshiba microwaves (Auto Cook and Inverter models) display codes on the digital screen when faults occur. These codes save hours of manual inspection. Call Toshiba microwave customer service 16062 and tell us the code — we'll give you the cause and estimated price.

Code Meaning Likely cause Est. cost Level
H95 Magnetron cooling fan fault Burnt fan motor, fan jammed by dust/grease, faulty magnetron temp sensor Starting from a price set after inspection Medium
H96 Inverter circuit board failure Board controlling wave modulation burnt, usually from voltage spike or lightning (Inverter models only) set after inspection Critical
H97 Touchpad membrane failure Worn touchpad membrane, water/tea leak inside, specific buttons unresponsive Starting from a price set after inspection Medium
H98 Main board or software fault Main control board burnt, processor programming fault, faulty EEPROM chip set after inspection Critical
H99 Humidity sensor failure for Auto Cook Humidity sensor for Auto Cook covered in grease, faulty, or wrong connection Starting from a price set after inspection Low
F1 Magnetron temperature sensor fault Magnetron temp sensor reading abnormal values, disconnected or faulty Starting from a price set after inspection Low
F2 Magnetron overheat protection Magnetron overheating, blocked vents, weak cooling fan Starting from a price set after inspection Medium
F3 Turntable motor fault Burnt or jammed turntable motor, faulty rotation sensor Starting from a price set after inspection Low
H95 Medium

Magnetron cooling fan fault

Burnt fan motor, fan jammed by dust/grease, faulty magnetron temp sensor

Starting from a price set after inspection
H96 Critical

Inverter circuit board failure

Board controlling wave modulation burnt, usually from voltage spike or lightning (Inverter models only)

set after inspection
H97 Medium

Touchpad membrane failure

Worn touchpad membrane, water/tea leak inside, specific buttons unresponsive

Starting from a price set after inspection
H98 Critical

Main board or software fault

Main control board burnt, processor programming fault, faulty EEPROM chip

set after inspection
H99 Low

Humidity sensor failure for Auto Cook

Humidity sensor for Auto Cook covered in grease, faulty, or wrong connection

Starting from a price set after inspection
F1 Low

Magnetron temperature sensor fault

Magnetron temp sensor reading abnormal values, disconnected or faulty

Starting from a price set after inspection
F2 Medium

Magnetron overheat protection

Magnetron overheating, blocked vents, weak cooling fan

Starting from a price set after inspection
F3 Low

Turntable motor fault

Burnt or jammed turntable motor, faulty rotation sensor

Starting from a price set after inspection
Diagnostic Mode

Self-Diagnostic Mode in Toshiba Microwaves

Modern Toshiba microwaves have a self-diagnostic mode that can detect magnetron, capacitor, and fan faults. Our technicians use it for accurate diagnosis before disassembling the unit and safely discharging the capacitor.

How to enter test mode

  1. 1 Unplug the microwave for 5 minutes (important for partial capacitor discharge)
  2. 2 Plug back in and press Stop/Clear
  3. 3 Press Power + 0 buttons together for 3 seconds
  4. 4 Diagnostic screen appears with last code and magnetron operating hours
  5. 5 To exit: press Stop/Clear twice

What it tests

1
Magnetron Output Test Place a 250mL cup of water inside and run at full power for 1 minute. Normal: 30-35°C rise. If rise is less than 15°C = magnetron needs replacement.
2
Door Safety Switches Test Continuity check of each of the three switches with multimeter — precisely identifies the faulty switch.
3
HV Capacitor Test After discharging with specialized tool, measure capacitance with multimeter — determines if capacitor is faulty or within spec. Sensitive operation requiring specialist.
4
Humidity Sensor Test Place moist food and run Auto Cook, monitor sensor response — determines if sensor is grease-covered or faulty.
Pricing

Toshiba Microwave Repair Prices — Original Parts & Labor Fees

Transparent prices for original Toshiba microwave parts and labor. Final price set after inspection and before starting — no surprises.

Spare Parts

16
  • Original Toshiba Magnetron The microwave's core component — Japanese-made vacuum tube
    set after inspection
  • High Voltage Capacitor 4,000V capacitor powering the magnetron
    set after inspection
  • High Voltage Diode Diode doubling voltage to 4,000V
    set after inspection
  • High Voltage Transformer Transformer stepping voltage from 220V to 2,000V
    set after inspection
  • Inverter Board (Inverter Microwave models) Wave modulation board (Inverter models only)
    set after inspection
  • Main Control Board Main electronic control board
    set after inspection
  • Touchpad Membrane Touchpad / membrane panel
    set after inspection
  • Door Safety Switch One of the three safety switches
    set after inspection
  • Turntable Motor Motor rotating the glass turntable
    set after inspection
  • Magnetron Cooling Fan Magnetron cooling fan
    set after inspection
  • Waveguide Cover (Mica) Mica sheet — cheapest part but most common sparking cause
    set after inspection
  • Humidity Sensor Humidity sensor for Auto Cook
    set after inspection
  • Toshiba Glass Turntable Original glass turntable
    set after inspection
  • Turntable Roller Ring Plastic ring with rollers under turntable
    set after inspection
  • Main Fuse / HV Fuse Electrical protection fuse
    set after inspection
  • Quartz Grill Element Quartz grill element (grill models only)
    set after inspection

Labor & Inspection Fees

  • Technical inspection with safe capacitor discharge set after inspection (included with repair)
  • Deep interior & exterior cleaning set after inspection
  • Control board reprogramming set after inspection

⚠️ Pricing notice: All prices listed are estimates only and vary based on the age, type, model, and condition of the device, as well as market fluctuations over time. Prices reflect the current Egyptian market and are updated periodically. The minimum for any visit and repair starts from a price set after inspection and extends to a wider range based on the fault. The final exact price is determined after the technician's on-site inspection and before starting.

Care & Maintenance

Toshiba Microwave Preventive Maintenance — 7 Tips to Extend Its Life

Japanese Toshiba microwaves last 10-12 years with simple preventive maintenance. Following these tips reduces major failures (magnetron) by 70%.

Weekly

Clean the microwave interior every week

Food and grease residue on interior walls cause sparking and burn the mica cover. Place a cup of water + sliced lemon, run 2 minutes, then wipe with damp cloth. Zero cost, prevents 90% of sparking issues.

Daily

Never run the microwave empty

Running the microwave with no food or liquid bounces magnetron waves back to source and burns it instantly. #1 cause of premature magnetron failure. To test the unit, always place a cup of water inside.

Daily

Don't use metal containers or aluminum foil

Any metal inside the microwave causes instant sparking and can burn the magnetron and mica cover. Use Pyrex glass, ceramic without metallic patterns, or microwave-safe plastic.

Yearly

Install a small voltage stabilizer (1 KVA)

Egypt's voltage fluctuation causes 50% of Inverter board and control board failures. A 1 KVA stabilizer (a price set after inspection) is sufficient for Toshiba microwaves up to 1100W, protecting electronics from burnout. Saves set after inspection board replacement cost.

Daily

Don't slam the door or open while running

Slamming the door quickly breaks the three door safety switches. Opening during operation harshly triggers the Monitor Switch and may burn it. Press Stop first, then open gently.

Daily

Don't block the ventilation slots

Ventilation slots in back and sides are essential for magnetron cooling. Don't install in a closed cabinet — leave at least 10cm on all sides. Blocked vents lead to code H95 and burnt magnetron.

Yearly

Book annual checkup every 12 months

Annual checkup with Agent Site (a price set after inspection per visit) includes: magnetron output measurement, capacitor test, door safety switches check, deep internal/external cleaning, ventilation check. Catches faults before they happen and saves thousands of pounds.

Customers

Toshiba Microwave Repair Reviews — Real Customer Experiences

My 34L Toshiba grill microwave is 9 years old. Suddenly started sparking inside with loud crackling. I was worried it was a major issue. Called the Toshiba microwave service number 16062 — technician arrived in 80 minutes, examined the unit, found the mica cover was burnt. Replaced at a price set after inspection and deep-cleaned the interior. Whole issue fixed in 35 minutes. I had expected a price set after inspection.

MM-EM34P(BS) (34L Grill)
أمل عبد الرحيم مدينة نصر - السوق التجاري

My 31L Toshiba Inverter microwave is 5 years old. Started running but not heating at all. Every Alexandria shop said it was the magnetron and would cost a price set after inspection+. Called Toshiba microwave customer service 16062 — technician came from Cairo in 4 hours, examined precisely, found the issue was a bulged HV capacitor (not the magnetron). Replaced for just a price set after inspection. Saved me thousands.

ML2-EM31P(BS) (31L Inverter)
سعيد المتولي الإسكندرية - محرم بك

My 3-in-1 Toshiba microwave (42L convection model) suddenly went totally dead — black screen, won't turn on. The Agent Site technician arrived in 50 minutes, confirmed the main fuse was blown from a sudden power cut. Replaced the fuse at a price set after inspection and advised installing a small voltage stabilizer. Saved me the cost of a main control board that would have cost over a price set after inspection.

ML-EM45P(BS) (42L 3-in-1)
نادية عاشور الجيزة - الدقي

My 24L Toshiba grill microwave (the best-seller). Door became hard to open and sometimes the unit says door is open when it's closed. Called Toshiba customer service 16062 — they advised inspection in Mansoura without transporting the unit. Technician arrived in 3 hours, found one of the 3 door safety switches was broken. Replaced at a price set after inspection. Learned that leaving the issue would have caused a Monitor Switch short that destroys the whole capacitor.

MW2-AG24P(BK) (24L Grill)
FAQ

Toshiba Microwave Repair — Frequently Asked Questions

Answers to the most common questions our Toshiba microwave customer service 16062 receives every day.

What's the unified Toshiba microwave service number in Egypt?
The unified Toshiba microwave service number is 16062 — one number for all Toshiba microwave types (solo, grill, inverter, 3-in-1) and every governorate. Hotline open now 24/7 including holidays.
My Toshiba microwave runs but doesn't heat — what does it mean?
This is the most common Toshiba microwave symptom — 70% of cases after 8 years are due to a burnt magnetron. The other 30%: bulged HV capacitor, burnt diode, or faulty transformer. Price ranges from a price set after inspection (diode) to a price set after inspection (original magnetron). Call 16062 for accurate phone diagnosis.
Is it safe to repair my Toshiba microwave myself?
No, very dangerous. Toshiba microwaves contain a capacitor that stores 4,000V charge even days after unplugging. Any attempt to open the unit without specialized discharge tools and safety training can cause fatal shock. Death cases have been documented in Egypt from DIY attempts. Leave repair to a specialist — call 16062.
My Toshiba microwave is sparking inside — what do I do?
Turn off the unit immediately and call 16062. In 80% of cases, the cause is a burnt waveguide cover (mica) — a very simple repair for just a price set after inspection. Ignoring it leads to magnetron burnout costing set after inspection. Inspection fee (included with repair), and the fix takes 30 minutes.
Is it worth repairing an old Toshiba microwave or should I buy new?
Rule: if repair cost is less than 40% of new unit price, repair is worth it. Example: a 24L Toshiba grill microwave market price is a price set after inspection. If repair is under a price set after inspection (e.g., magnetron at a price set after inspection), repair. If more and multiple faults piled up, consider buying new. Call 16062 for accurate evaluation.
Do you service Toshiba microwaves in Alexandria and Mansoura?
Yes, Agent Site covers 17+ areas in Egypt including Alexandria, Mansoura & Dakahlia, Tanta, Zagazig, and every governorate. Arrival time 2-4 hours in governorates. Customer service 16062 identifies the nearest specialized Toshiba microwave technician in your area.
How long does Toshiba microwave repair take?
Inspection takes 30 min. Simple repairs (mica cover, fuse, door switch, turntable motor) 30-60 min. Mid repairs (capacitor, diode, sensor) 1-2 hours. Major repairs (magnetron, transformer, Inverter board, main control) 2-4 hours. All same-day in Greater Cairo.
Is there a warranty on Toshiba microwave repair?
Yes, every repair comes with an official invoice and 6-month documented warranty on both the repair and replaced parts. The original magnetron has a written 12-month warranty. If the same fault recurs within the warranty period, we re-repair completely free.
Available 24/7

Need Toshiba Microwave Repair Right Now? — Call 16062 (Open Now 24/7)

Unified Toshiba microwave service number 16062 — instant phone diagnosis for all error codes (H95, H96, H97, H98, H99, F1, F2, F3), find the nearest specialized Toshiba microwave technician trained in safe capacitor discharge, get an estimated price before the technician arrives, and a home visit within 1 hour in Greater Cairo. Original Toshiba magnetron with 12-month warranty + original Toshiba parts + 6-month documented warranty on the repair + official invoice. 7-day service open now, Fridays and holidays included at the same standard pricing.

1-hour response
6-month warranty
Original parts