Technician repairing a PTAC unit under a hotel room window
Calls 24h · Visits 9 AM–9 PM

Hotel Room AC Repair in Egypt

Single and central hotel room AC service with low noise levels

6-month written warranty on the repair and the replaced part

Agent Site is an independent repair center — not the manufacturer's authorized service or warranty provider.

Written warranty6 months
Formal invoiceOn every visit
Spare partsOriginal or compatible
Visit hoursVisits 9 AM–9 PM

We repair guest-room ACs in hotels and serviced apartments — PTAC, fan coil and VRF: water leaks, weak cooling, loud noise and odours.

The 16062 hotline answers calls 24 hours; technician visits run daily 9 AM–9 PM at the earliest available slot for your area.

Hotel Room ACs Service with Agent Site

A guest-room AC runs for long hours, and any problem — a water leak, weak cooling, loud noise or a smell — reaches the guest quickly. We repair the three types common in hotels: PTAC units (a complete unit under the window or in a wall opening), fan coil units (FCU) fed with chilled water from a central chiller, and VRF/VRV systems where one outdoor unit serves several indoor units.

Our technicians work on systems from brands such as Daikin, Mitsubishi Electric, LG, Carrier, Trane and others. The service covers: finding and fixing refrigerant leaks before recharging (R-410A, R-32 or R-407C), replacing the outdoor-unit or PTAC compressor, cleaning coils and filters, clearing drain pans and drain lines, and repairing control and inverter boards — with original or compatible parts depending on the part and model.

  • PTAC, fan coil and VRF/VRV repair
  • Technicians who work on Daikin, Mitsubishi, LG and Carrier systems
  • Coil and drain-pan cleaning to get rid of musty smells
  • Visits daily 9 AM–9 PM at the earliest available slot
  • Inspection visits for several rooms, as agreed with the hotel

Hotel Room ACs Services

Book a service
  • Leak Detection and R-410A / R-32 / R-407C Charging
  • Outdoor-Unit or PTAC Compressor Replacement
  • Coil and Heat Exchanger Cleaning
  • Filter Replacement
  • Deep Cleaning and Disinfection of the Unit and Drain Pan
  • Drain Pan and Drain Line Repair
  • Refrigerant Line Inspection and Leak Testing
  • Inverter and Control Board Repair
  • Remote and Wired Controller Replacement
  • Fan and Fan Motor Repair
  • New Room AC Installation with All Connections
  • Periodic Maintenance Contracts for Hotels

Hotel Room ACs Types We Service

PTAC Unit Repair for Hotels

PTAC (packaged terminal air conditioner) repair for hotels — a complete unit (compressor, evaporator and condenser) in one box under the window or in a wall opening. Common in budget and mid-range hotels because installation is simple and each room is independent. Well-known brands include Carrier, Trane, Friedrich, GE Zoneline and Amana.

A PTAC is a through-the-wall unit with an indoor section (evaporator, fan, filter) and an outdoor section (compressor, condenser, fan), separated by insulation. It is installed in a wall/under-window opening of a standard 42x16 inch size. Faults: an aging compressor, low refrigerant, a clogged drain pan (water leaking onto the carpet!), dirty filters, a musty smell, and loud noise.

Signs it needs service

  • The unit does not cool to the setpoint
  • Water leaking from the drain pan onto the carpet
  • A very loud compressor noise (disturbing the guest)
  • A musty smell from the vents
  • The unit shuts itself off after a few seconds
  • The electricity bill suddenly jumped
  • The remote controller does not respond
  • The filters are completely black from grease and hair

Common faults

  1. A clogged drain pan and water leakage (one of the most common faults)
  2. Mould and fungus on the evaporator
  3. Low refrigerant from a small leak
  4. An aging compressor with reduced efficiency
  5. A failed indoor fan motor
  6. Filters clogged with dust and hair
  7. A failed electronic thermostat
  8. A failed remote controller / wall switch

What we do

  • Clearing the clogged drain pan and replacing the drain hose
  • Deep cleaning and disinfection of the evaporator and drain pan
  • R-410A refrigerant charging and leak detection
  • Compressor replacement
  • Fan motor replacement
  • Filter replacement
  • Thermostat replacement
  • Remote controller / wall switch repair
  • Inspection of PTAC units across several rooms, as agreed
  • New PTAC installation and wall sleeve repair

Care tips

  • Clean the filters regularly and replace them when torn or worn
  • Check the drain pan monthly (a leak onto the carpet is costly)
  • Deep-clean the unit every 6 months to prevent odours
  • Make sure the wall sleeve is tightly sealed (outside air leakage wastes energy)
  • Replace the remote battery in every room annually

Questions

A PTAC unit is dripping water onto the carpet — what should I do?

Usually the drain pan is blocked. Switch the unit off, put a towel under the drip and call 16062 — we book the earliest available visit to clear the drain and replace the hose if needed.

Do you repair Carrier PTAC units?

Yes — we repair Carrier PTAC units and other brands, with original or compatible parts depending on the part and model, and a 6-month written warranty on the repair and the replaced part.

The compressor is very loud and the guest is complaining — why?

Usually the compressor is weakening or the rubber mounts that hold it are worn. An inspection will tell; the fix may be new mounts, a new compressor, or replacing the whole unit if it is very old.

Fan Coil Unit Repair for Hotels

Fan coil unit (FCU) repair for hotels — an indoor-only unit (cooling coil, fan and filter) connected to the hotel's central chiller by chilled-water pipes, so there is no refrigerant or compressor in the room. Well-known models include the Carrier 42N and Trane UniTrane.

A fan coil has a copper cooling coil fed with chilled water from the chiller, a fan with several speeds (usually 3), a filter and a drain pan — sometimes with a condensate pump — plus a thermostat or controller. Common faults: the fan motor, a coil blocked by dust, the condensate pump (water leaks), the three-way valve or its actuator, and the thermostat.

Signs it needs service

  • The unit is not cooling even though the chiller is running
  • The fan runs but there is no cold air
  • Water leaking from the condensate pump
  • A loud, irregular fan noise
  • The three-way valve is not controlling the water
  • An odor from the cooling coil

Common faults

  1. A failed fan motor (capacitor or winding)
  2. A cooling coil blocked by dust
  3. A failed condensate pump
  4. A failed three-way valve or its actuator
  5. A failed thermostat / controller
  6. Leakage from the coil connections

What we do

  • Fan motor and capacitor replacement
  • Deep cooling coil cleaning
  • Condensate pump replacement
  • Three-way valve or actuator replacement
  • Thermostat replacement
  • Repair of coil connection leaks
  • Filter replacement
  • Inspection of fan coil units across several rooms, as agreed

Care tips

  • Clean the cooling coil every 6 months — dust noticeably reduces efficiency
  • Check the condensate pump regularly — a leak damages the ceiling of the room below
  • Clean or replace the filters every 2-3 months depending on use
  • Make sure the earth ground is connected (water plus electricity is dangerous)

Questions

The fan coil is dripping water from the ceiling — what should I do?

Usually the condensate pump has failed or the drain is blocked. Switch the unit off at the thermostat; if the water is near ceiling lights or wiring, isolate that circuit at the panel, put a bucket under the drip and call 16062 — we book the earliest available visit.

The unit is not cooling even though the chiller is running?

Either the cooling coil is blocked, the three-way valve or its actuator has failed, or the thermostat is faulty. An inspection will determine it.

Do you repair Carrier and Trane fan coils?

Yes — we repair Carrier fan coils (such as the 42N series), Trane and other brands, with original or compatible parts depending on the part and model.

VRV / VRF System Repair for Hotels

VRF / VRV system repair for hotels — one outdoor unit serves several indoor units (the number depends on the model), and each room controls its own temperature. Well-known systems include Daikin VRV, Mitsubishi Electric City Multi, LG Multi V, Toshiba SMMS, Hitachi Set-Free, Samsung DVM and Panasonic ECOi.

A VRF system is among the most complex air conditioning systems: an outdoor unit with inverter compressors and heat exchangers, a long refrigerant piping network, multiple indoor units (cassette, wall-mounted or concealed ducted), branch selectors and a central controller. Common faults: the outdoor inverter board, refrigerant leaks in the piping network, compressor failure, an indoor-unit board, or the branch selectors.

Signs it needs service

  • One of the indoor units is not cooling
  • An abnormal noise from the outdoor unit
  • An error code on the central controller
  • Electricity consumption suddenly rose
  • Some rooms are very cold, others are not cold
  • A suspected refrigerant leak (needs leak detection)
  • The outdoor unit short-cycles (stops and starts quickly)

Common faults

  1. A failed inverter board in the outdoor unit (one of the most common faults)
  2. A refrigerant leak from the piping network
  3. Compressor burnout (rare but costly)
  4. A failed indoor PCB on a specific unit
  5. A failed branch selector / distributor
  6. Failed temperature and pressure sensors
  7. Blocked heat exchangers in the outdoor unit
  8. A failed communication cable between outdoor and indoor units

What we do

  • Reading fault codes and operating data with diagnostic tools suited to the model
  • Inverter board replacement in the outdoor unit
  • Refrigerant leak repair and recharging by weight (R-410A or R-32, depending on the system)
  • Compressor replacement
  • Indoor PCB repair
  • Branch selector replacement
  • Sensor replacement
  • Heat exchanger cleaning
  • Communication cable repair
  • A nitrogen pressure test of the piping network

Care tips

  • A VRF system needs regular scheduled maintenance from its first year
  • Check the outdoor unit monthly (heat-exchanger cleanliness and clearance around it)
  • Log the error codes shown on the central controller
  • Fit protection against voltage fluctuations — the surge when power returns after a cut can damage inverter boards
  • Have a technician review system pressures and operation at the annual service

Questions

A Mitsubishi City Multi system is showing an error code — what should I do?

City Multi codes vary by model and controller. Send us the code and a photo of the display on WhatsApp, and the technician will work out the likely cause before the visit.

There is a refrigerant leak in the piping network — can it be fixed without replacing all the pipes?

Usually yes — the technician locates the leak with a nitrogen pressure test and a leak detector. If the leak is at a single joint it is repaired locally and the system is recharged by weight; if there are several leaks, part of the piping may need replacing.

Hotel Room ACs service areas

We cover Cairo, Giza, Qalyubia, Alexandria, Matrouh (North Coast), Sharqia, Gharbia, Dakahlia. Not sure about your area? Call 16062 and we confirm before booking.

  • Cairo
  • Giza
  • Qalyubia
  • Alexandria
  • Matrouh (North Coast)
  • Sharqia
  • Gharbia
  • Dakahlia

How We Work

  1. 01

    Call 16062

    Tell us the AC type (PTAC/FCU/VRF), the brand and the number of affected rooms.

  2. 02

    Inspection of Every Affected Room

    The technician goes room by room (in coordination with Housekeeping), inspects every unit and records its condition.

  3. 03

    Report + Plan

    A report for hotel management + a list of faults + a repair plan (Urgent / Standard / Preventive).

  4. 04

    Repair + Deep Cleaning

    Repair with original or compatible parts depending on the part and model + cleaning and disinfection + a cooling test.

  5. 05

    Report + Warranty

    A report of the work done + a formal invoice + a 6-month written warranty on the repair and the replaced part.

Book your ac service

at the earliest available slot for your area

  • 6-month written warranty on the repair and the replaced part
  • Technician visits daily from 9 AM to 9 PM
Call now16062

Your service details

We save your request and call you to confirm the appointment; WhatsApp opens with the details too.

Why Agent Site?

Clear Visit Hours

The 16062 hotline answers 24 hours; visits run daily 9 AM–9 PM at the earliest available slot for the hotel's area.

Expertise Across 3 Hotel Systems

PTAC, fan coil and VRF — each system needs a different kind of maintenance, and our technicians work on all three.

Cleaner Room Air

Cleaning the coil and filters and clearing the drain pan removes the source of musty smells and standing water.

Multi-Room Inspections

We can arrange a visit with the hotel team to check the ACs in several rooms, with a report on each unit.

Tips to Extend Your AC's Life

  • Clean the unit filters every two weeks during the cooling season
  • Deep-clean the coil and drain pan every 6 months
  • Check the drain pans regularly — standing water is the main cause of odours
  • Check cooling performance monthly (supply vs return air temperature); have the refrigerant pressure measured only if an undercharge is suspected
  • If you log power use per room, a sudden rise flags a hidden fault early
  • Fit voltage protection to protect the inverter boards

Frequently Asked Questions

What is the difference between PTAC, Fan Coil and VRF?

PTAC: a complete self-contained unit (compressor, evaporator and condenser) in the room — simple installation and lower cost. Fan coil: an indoor unit only, connected to a central chiller by chilled-water pipes — common in mid-size and large hotels. VRF: one outdoor unit serving several indoor units, with separate control in each room — common in large hotels.

Do you work on Daikin VRV and Mitsubishi VRF?

Yes — we work on Daikin VRV, Mitsubishi City Multi, LG Multi V and other systems: reading fault codes, leak detection and board repair, with original or compatible parts depending on the part and model.

A musty smell from the room AC — what causes it?

A musty smell usually comes from mould on the coil or standing water in the drain pan — cleaning and clearing the drain fixes it. If the smell comes back quickly, the technician checks the pan slope and the drain hose.

Is there an annual maintenance contract covering every AC unit in the hotel?

Yes — we offer periodic maintenance contracts for hotels; the details (number of visits, cleaning and reports) are set after a survey, based on the number and type of units.

Do you install a new VRF system for a new hotel?

A new VRF installation is a project that is scoped after a site survey and a load study — call 16062 and we will review the request with you.

How long do hotel room ACs last?

It depends on running hours and maintenance. As a rough guide, PTAC units have the shortest life because they run constantly (often around 10 years), while fan coils and VRF systems last longer (often 15 years or more) with regular maintenance.

Do you serve hotels on the coast and in resort towns?

We serve hotels in Alexandria and Matrouh (North Coast), as well as Cairo, Giza and our other covered governorates. Sharm El-Sheikh, Hurghada, the Red Sea towns and Upper Egypt are not in our service area at the moment.

Technician repairing a PTAC unit under a hotel room window
Hotline 16062 answers calls around the clock

Need an AC technician for your guest rooms?

AC down in a guest room? Call 16062 any time and we will book the earliest available visit between 9 AM and 9 PM.

← All devices